Features
- Offline UPS
- Compact size
- Quick installation and easy operation
- Excellent microprocessor control
- Discharge, overcharge and overload protection
- Visiual and audible Alarm system
- Simulated sine wave output
- Cold start function
- USB port
- RJ11/45 protection
| MODEL | PowerMust 800 offline | |
| INPUT | ||
| Capacity | 800VA/400W | |
| Nominal Voltage | 220/230/240 VAC | |
| Voltage Range | 180-270 VAC | |
| Frequency Range | 50/60 Hz (auto sensing) | |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | ± 10% | |
| Frequency Range (Batt. Mode) | 50 / 60 Hz ± 1 Hz | |
| Transfer Time | Typical 2-6 ms, 10 ms max. | |
| Line Mode Voltage | Same as input voltage | |
| Waveform (Batt. Mode) | Simulated Sinewave | |
| Protection | Discharge, Overcharging and Overload protection | |
| BATTERY | ||
| Battery Type | 12 V / 5 AH x 1 | |
| Recharge Time | 4-6 hours (recharge to 90% capacity) | |
| Backup Time (half Load) | 5 min | |
| INDICATORS | ||
| Line Mode Normal | Green lighting | |
| Battery Normal | Yellow flashing | |
| Battery Low | Yellow flashing | |
| Fault | Red lighting | |
| AUDIBLE ALARM | ||
| Battery Mode | Sounding every 10 seconds | |
| Low Battery at battery mode | Sounding every second | |
| Fault | Continuously sounding | |
| Overload | Sounding every 0.5 second | |
| PHYSICAL | ||
| Dimension, D x W x H (mm) | 305 x 158,5 x 95 | |
| Net Weight (kgs) | 2,9 | |
| ENVIRONMENT | ||
| Operation Humidity | 0-90% RH @ 0-40˚ C (non-condensing) | |
| INTERFACE | ||
| Power Cord Connector | IEC inlet | |
| Outlet | Schuko x 6 ( 3 for surge only, 3 for battery backup) | |
| Phoneline/ Network protection R45 | Yes | |
| – | ||
| LED/LCD | LED x 3 | |